Roof slope of 3 12.
2 hour roof truss assembly.
Shaft wall limiting heights spans.
Layer 3 trusses.
O c fabricated from nom.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.
Our cad and revit library of design drawings of wall intersections joints and other construction details.
One basis for this type of analysis is harmathy s ten rules of fire endurance rating written in 1965.
2 hour fire endurance assembly for mpcwt structural floor and roof framing systems educational overview revised 10 2 2017.
Find usg product specific cad and revit files.
Pitched or parallel chord wood trusses spaced 24 max.
1 5 hours nominal 2x3 24 oc min 10 depth truswal truss plates trusgard protective channels applied to bottom chord of each truss fire rated suspended ceiling min 7 1 2 below the truss sheathing min 3 4 nominal 2x3 24 oc min 10 depth truswal truss plates fire rated suspended ceiling min 7 1 2 below the truss sheathing min 3 4 fr.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
Sbca endeavors to expand component manufacturers.
Refer to our roof ceiling assembly documents which includes ul fire rated roof assemblies for easy guidance through the assembly of a roof or ceiling on your next project.
Sound tested with 2 x 4 stud wall with 1 2 12 7 mm toughrock fireguard c gypsum wallboard or densarmor plus fireguard c panels each side of assembly and 3 1 2 89 mm fiberglass insulation in stud space both sides.
Achieving a 2 hour floor ceiling assembly from the underside only home articles achieving a 2 hour floor ceiling assembly from the underside only one of our current projects is a change of occupancy where the change will require a 2 hour rating between the main level a 2 occupancy and the r 2 occupancy above.
Helpful documents and resources for usg s roof assemblies can be found on this page.
Breakaway clip facings and height of wall differ between ul design u373 and whi gp wa 120 04.
A two hour assembly has been calculated and a copy of the report is available from sbca sbca srr 1509 02.
Truss depth shall be 5 1 4 with a min.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.
Building codes may require construction assemblies to have a fire resistance rating such as 1 hour 1 hour and 2 hour in specific construction types and occupancies.
Fire rated cold formed steel truss assemblies to properly design a building for fire safety building designers must recognize and accurately follow building fire code regulations.