I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
1 hour roof truss assembly.
With 1 25 mm type s drywall screws 12 305 mm o c.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
Wood truss council of america floor or roof fire notes 1.
C roof ceilings45 51 steel framed including steel bar joist framing steel c joist framing steel truss and.
Layer 3 trusses.
See full report for details.
O c fabricated from nom.
Resilient channels attached 16 406 mm o c.
Roof slope of 3 12.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Fire safety building assembly s the period of time the assembly will serve as a barrier to the spread.
Engineered joist and truss.
No minimum joist size is given except that it needs to be adequate for structural loads.
I am looking for a 1 hour roof ceiling assembly for wood truss construction.
1 one hour and two hour rated assemblies that may be used in the roof cavity and that may be constructed with gable end frames.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.
2x4 lumber oriented vertically or horizontally.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
Ibctable 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.
With 1 2 wood structural panels with exterior glue applied at right angles to top of joist or top chord of trusses with 8d nails.
Through base layer perpendicular to.
Pitched or parallel chord wood trusses spaced 24 max.
Assemblies include ducts dampers lighting or other fixtures in the tested assembly.
Maximum with 1 5 8 41 mm type s drywall screws 8 203 mm o c.
Figure 17 3 2 figure 17 3 2.
In this case a single layer of 1 2 gypsum wallboard is attached to the side of a single roof truss in the location shown to provide the required draftstop and area separation.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
Is this possible without using channels and what ul number would i use.
Truss depth shall be 5 1 4 with a min.
Ibc section 722 6 could be used to calculate up to a 1 hour rating for a wood frame wall floor or roof assembly.
Ibc table 722 6 2 2 allows 10 minutes for wood floor or roof joists at 16 o c.
Figure 17 3 2 shows an alternative roof detail to that in figure 17 3 1 in which the roof trusses are parallel to the wall assembly.